Contact Us

If you see this, leave this form field blank and invest in CSS support.

How to Order

CALL NOW!

(828) 708-7178

Summer/Winter Universal - 24 Hr Specimen Transport Kit at Controlled Room Temperature for Blood Specimens

It is challenging to maintain a single pack-out procedure all year long for blood specimen integrity. In winter, the specimen needs to stay above +15°C while ambient conditions range from -10°C to +10°C; and during summer, the specimen needs to stay below +30°C while ambient conditions range from +20°C to +35°C regular gel packs cannot provide the precise holdover temperature of +15°C.

The AkuraTemp™ ATS3 Thermal Specimen Shipper engineered for Controlled Room Temperature is convenient and simple to use. It provides reliable protection for blood, serum, tissue and other specimens. Accommodates tubes, vials, ampules, Petri dishes, small bottles and tissue flasks. The payload is packaged within the primary and secondary bio-hazard bags and then placed between a cassette of two savENRG™ CRT Packs & savENRG™ Warm Packs for efficient temperature control between +15°C to +30°C for 24 hours. The pack-out is universal for Winter and Summer. The temperature control packs can be stored at room temperature (between +20°C to +22°C). The kit is efficient for standard overnight transport allowing for specimen integrity in case of any transit delays. It maintains the samples at safe temperatures regardless of power outages or missed courier pickups. The CRT Specimen Transport Kit is ideal for applications in clinical trials and direct-to-lab deliveries. It fits into FedEx Clinical Pak and FedEx UN3373 Pak.

FeaturesSpecifications
  • 24 hr hold-over time
  • Lightweight
  • Simple pack out procedure
  • Condition and store at room temperature
  • Temperature range: +15°C to +30°C
  • Performance: 24 hr
  • Payload area: 6” X 4.5” X 2”
  • Exterior dimensions: 8”x6.5”x4.5”
  • Max. payload: 4 vials of 10 ml

Ordering Instructions

Model Description
ATS1-1829PP5-24 Specimen transport kit with two 5x6” PCM-OM18P & two5x6” PCM-HS29P pouches within a 1” - closed cell PUF insulated blocks in 8”x6.5”x4.5” box.
18PP5 Set of two savENRG™ CRT Packs 5x6”. Case of 12”x8”x8” with 25 sets
29PP5 Set of two savENRG™ Warm Packs 5x6”. Case of 12”x8”x8” with 25 sets
ATS3 1” - closed cell PUF insulated blocks in 8”x6.5”x4.5” box
akuraSENSE Temperature logger for BioMed applications. Operating range of -20C to +60C. Embedded NIST certificate. 15 month shelf life. 55 to 110days recorded life.